Horizon
AVVenues

Hall H at Indiana Convention Center & Lucas Oil Stadium

Published dimensions

Hall H is 73.2 x 95.4 m (240 x 313 ft), 6,983 m² (75,168 sq ft), with a 10.7 m (35 ft) ceiling.

Open in 3D previz

Plan view

73.2 m / 240 ft95.4 m / 313 ft grid 10 m

LED wall that fits

Under a 10.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 17 rows of 500 mm tile flown. Along the 95.4 m wall a Absen PL2.5 Plus V2 wall runs 152 x 17 (30400 x 3400 px, 20,155 kg, 413.4 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm127 x 26 = 330276.2 x 8.8 m97536 x 1123214,859 kg / 32,758 lb292.2 kW, 1405 A @ 208 V
Absen PL2.5 Plus V22.5 mm152 x 17 = 258476 x 8.5 m30400 x 340020,155 kg / 44,434 lb413.4 kW, 1988 A @ 208 V
Absen PL3.9 Plus V23.9 mm152 x 17 = 258476 x 8.5 m19456 x 217620,155 kg / 44,434 lb361.8 kW, 1739 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall H holds about 15,331 theater seats, 6,272 banquet seats at rounds of 10, or 4,312 classroom seats. Back row in theater is roughly 88.4 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Indiana Convention Center & Lucas Oil Stadium

Published dimensions (source), fetched 2026-09-04. All rooms at Indiana Convention Center & Lucas Oil Stadium · Venues in Indianapolis

Menu
Sign InStart Free Trial