Published dimensions

Hall G is 36 x 76.2 m (118 x 250 ft), 2,743 m² (29,528 sq ft), with a 10.7 m (35 ft) ceiling.

Open in 3D previz

Plan view

36 m / 118 ft76.2 m / 250 ft grid 10 m

LED wall that fits

Under a 10.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 17 rows of 500 mm tile flown. Along the 76.2 m wall a Absen PL2.5 Plus V2 wall runs 121 x 17 (24200 x 3400 px, 16,045 kg, 329.1 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm101 x 26 = 262660.6 x 8.8 m77568 x 1123211,817 kg / 26,052 lb232.4 kW, 1117 A @ 208 V
Absen PL2.5 Plus V22.5 mm121 x 17 = 205760.5 x 8.5 m24200 x 340016,045 kg / 35,372 lb329.1 kW, 1582 A @ 208 V
Absen PL3.9 Plus V23.9 mm121 x 17 = 205760.5 x 8.5 m15488 x 217616,045 kg / 35,372 lb288 kW, 1385 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall G holds about 5,909 theater seats, 2,417 banquet seats at rounds of 10, or 1,661 classroom seats. Back row in theater is roughly 69.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.