Published dimensions

Hall F is 64 x 75.6 m (210 x 248 ft), 4,838 m² (52,080 sq ft), with a 10.7 m (35 ft) ceiling.

Open in 3D previz

Plan view

64 m / 210 ft75.6 m / 248 ft grid 10 m

LED wall that fits

Under a 10.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 17 rows of 500 mm tile flown. Along the 75.6 m wall a Absen PL2.5 Plus V2 wall runs 120 x 17 (24000 x 3400 px, 15,912 kg, 326.4 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm100 x 26 = 260060 x 8.8 m76800 x 1123211,700 kg / 25,794 lb230.1 kW, 1106 A @ 208 V
Absen PL2.5 Plus V22.5 mm120 x 17 = 204060 x 8.5 m24000 x 340015,912 kg / 35,080 lb326.4 kW, 1569 A @ 208 V
Absen PL3.9 Plus V23.9 mm120 x 17 = 204060 x 8.5 m15360 x 217615,912 kg / 35,080 lb285.6 kW, 1373 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall F holds about 10,565 theater seats, 4,322 banquet seats at rounds of 10, or 2,971 classroom seats. Back row in theater is roughly 68.6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Indiana Convention Center & Lucas Oil Stadium

Published dimensions (source), fetched 2026-09-04. All rooms at Indiana Convention Center & Lucas Oil Stadium · Venues in Indianapolis