A Hall at Turku Fair And Congress Center
A Hall is 70 x 50 m (230 x 164 ft), 3,500 m² (37,674 sq ft), with a 12 m (39 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 12 m ceiling with 1.5 m trim and 0.3 m clearance you get 20 rows of 500 mm tile flown. Along the 70 m wall a Absen PL2.5 Plus V2 wall runs 112 x 20 (22400 x 4000 px, 17,472 kg, 358.4 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 93 x 30 = 2790 | 55.8 x 10.1 m | 71424 x 12960 | 12,555 kg / 27,679 lb | 246.9 kW, 1187 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 112 x 20 = 2240 | 56 x 10 m | 22400 x 4000 | 17,472 kg / 38,519 lb | 358.4 kW, 1723 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 112 x 20 = 2240 | 56 x 10 m | 14336 x 2560 | 17,472 kg / 38,519 lb | 313.6 kW, 1508 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, A Hall holds about 7,591 theater seats, 3,105 banquet seats at rounds of 10, or 2,135 classroom seats. Back row in theater is roughly 63 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Turku Fair And Congress Center
- C Hall70 x 50 m (230 x 164 ft) · 6 m ceiling
- B Hall60 x 50 m (197 x 164 ft) · 7 m ceiling
- D Hall60 x 50 m (197 x 164 ft) · 4 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Turku Fair And Congress Center · Venues in Turku