Horizon
AVVenues

Meeting Room 304 at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions

Meeting Room 304 is 13.1 x 16.5 m (43 x 54 ft), 216 m² (2,327 sq ft), with a 3.7 m (12 ft) ceiling.

Open in 3D previz

Plan view

13.1 m / 43 ft16.5 m / 54 ft grid 1 m

LED wall that fits

Under a 3.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 16.5 m wall a Absen PL2.5 Plus V2 wall runs 26 x 3 (5200 x 600 px, 608 kg, 12.5 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm22 x 5 = 11013.2 x 1.7 m16896 x 2160495 kg / 1,091 lb9.7 kW, 47 A @ 208 V
Absen PL2.5 Plus V22.5 mm26 x 3 = 7813 x 1.5 m5200 x 600608 kg / 1,341 lb12.5 kW, 60 A @ 208 V
Absen PL3.9 Plus V23.9 mm26 x 3 = 7813 x 1.5 m3328 x 384608 kg / 1,341 lb10.9 kW, 53 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 304 holds about 293 theater seats, 120 banquet seats at rounds of 10, or 82 classroom seats. Back row in theater is roughly 9.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions (source), fetched 2026-09-05. All rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) · Venues in Raleigh