Horizon
AVVenues

Exhibit Hall A+B at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions

Exhibit Hall A+B is 100.3 x 84.1 m (329 x 276 ft), 8,435 m² (90,796 sq ft), with a 9.8 m (32 ft) ceiling.

Open in 3D previz

Plan view

100.3 m / 329 ft84.1 m / 276 ft grid 10 m

LED wall that fits

Under a 9.8 m ceiling with 1.5 m trim and 0.3 m clearance you get 15 rows of 500 mm tile flown. Along the 100.3 m wall a Absen PL2.5 Plus V2 wall runs 160 x 15 (32000 x 3000 px, 18,720 kg, 384 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm133 x 23 = 305979.8 x 7.8 m102144 x 993613,766 kg / 30,347 lb270.7 kW, 1301 A @ 208 V
Absen PL2.5 Plus V22.5 mm160 x 15 = 240080 x 7.5 m32000 x 300018,720 kg / 41,270 lb384 kW, 1846 A @ 208 V
Absen PL3.9 Plus V23.9 mm160 x 15 = 240080 x 7.5 m20480 x 192018,720 kg / 41,270 lb336 kW, 1615 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Exhibit Hall A+B holds about 18,558 theater seats, 7,592 banquet seats at rounds of 10, or 5,219 classroom seats. Back row in theater is roughly 93.3 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center)

Published dimensions (source), fetched 2026-09-05. All rooms at Atlantic Union Bank Convention Center (formerly Raleigh Convention Center) · Venues in Raleigh