Horizon
AVVenues

Room 149AB at Walter E. Washington Convention Center

Published dimensions

Room 149AB is 19.5 x 8.2 m (64 x 27 ft), 160 m² (1,721 sq ft), with a 5.2 m (17 ft) ceiling.

Open in 3D previz

Plan view

19.5 m / 64 ft8.2 m / 27 ft grid 1 m

LED wall that fits

Under a 5.2 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 19.5 m wall a Absen PL2.5 Plus V2 wall runs 31 x 6 (6200 x 1200 px, 1,451 kg, 29.8 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm26 x 10 = 26015.6 x 3.4 m19968 x 43201,170 kg / 2,579 lb23 kW, 111 A @ 208 V
Absen PL2.5 Plus V22.5 mm31 x 6 = 18615.5 x 3 m6200 x 12001,451 kg / 3,198 lb29.8 kW, 143 A @ 208 V
Absen PL3.9 Plus V23.9 mm31 x 6 = 18615.5 x 3 m3968 x 7681,451 kg / 3,198 lb26 kW, 125 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Room 149AB holds about 168 theater seats, 69 banquet seats at rounds of 10, or 47 classroom seats. Back row in theater is roughly 12.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Walter E. Washington Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Walter E. Washington Convention Center · Venues in Washington