Horizon
AVVenues

Room 140AB at Walter E. Washington Convention Center

Published dimensions

Room 140AB is 19.1 x 15.7 m (63 x 52 ft), 300 m² (3,228 sq ft), with a 5.2 m (17 ft) ceiling.

Open in 3D previz

Plan view

19.1 m / 63 ft15.7 m / 52 ft grid 1 m

LED wall that fits

Under a 5.2 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 19.1 m wall a Absen PL2.5 Plus V2 wall runs 30 x 6 (6000 x 1200 px, 1,404 kg, 28.8 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm25 x 10 = 25015 x 3.4 m19200 x 43201,125 kg / 2,480 lb22.1 kW, 106 A @ 208 V
Absen PL2.5 Plus V22.5 mm30 x 6 = 18015 x 3 m6000 x 12001,404 kg / 3,095 lb28.8 kW, 138 A @ 208 V
Absen PL3.9 Plus V23.9 mm30 x 6 = 18015 x 3 m3840 x 7681,404 kg / 3,095 lb25.2 kW, 121 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Room 140AB holds about 479 theater seats, 196 banquet seats at rounds of 10, or 134 classroom seats. Back row in theater is roughly 12.1 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Walter E. Washington Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Walter E. Washington Convention Center · Venues in Washington

Menu
Sign InStart Free Trial