Published dimensionsWashington

Hyatt Place Washington DC/Georgetown/West End in Washington lists 8 event spaces totaling 523 m² (5,632 sq ft). The largest is Meeting Place 1-3 at 23 x 6.4 m (75 x 21 ft) with a 3 m (10 ft) ceiling. The tallest ceiling on the property is 3 m (10 ft).

Open Meeting Place 1-3 in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Meeting Place 1-323 x 6.475 x 21147 m² / 1,584 sq ft3 m / 10 ftPublished dimensions
Meeting Place 1 - 218.1 x 6.459 x 21116 m² / 1,246 sq ft3 m / 10 ftPublished dimensions
Meeting Place 112.8 x 6.442 x 2182 m² / 882 sq ft3 m / 10 ftPublished dimensions
Meeting Place 2 - 310.1 x 6.433 x 2165 m² / 695 sq ft3 m / 10 ftPublished dimensions
Meeting Place 25.2 x 6.417 x 2133 m² / 358 sq ft3 m / 10 ftPublished dimensions
Meeting Place 34.9 x 6.416 x 2131 m² / 338 sq ft3 m / 10 ftPublished dimensions
Boardroom B4.6 x 5.515 x 1825 m² / 272 sq ft3 m / 10 ftPublished dimensions
Boardroom A4.3 x 5.514 x 1824 m² / 255 sq ft3 m / 10 ftPublished dimensions

What fits in Meeting Place 1-3

With a 3 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 36 tiles wide by 2 high (72 tiles, 18 x 1 m, 7200 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 562 kg and draws up to 11.5 kW (55 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 140 theater, 57 banquet, or 39 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm30 x 3 = 9018 x 1 m23040 x 1296405 kg / 893 lb8 kW, 38 A @ 208 V
Absen PL2.5 Plus V22.5 mm36 x 2 = 7218 x 1 m7200 x 400562 kg / 1,238 lb11.5 kW, 55 A @ 208 V
Absen PL3.9 Plus V23.9 mm36 x 2 = 7218 x 1 m4608 x 256562 kg / 1,238 lb10.1 kW, 48 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 8 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Meeting Place 1-3 is a long room (3.6:1), so put the wall on the short end and expect the back row to be 23 m out; a 2.5 mm pitch holds up at that distance.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.