Hilton Garden Inn Washington DC Downtown

Published dimensionsWashington

Hilton Garden Inn Washington DC Downtown in Washington lists 9 event spaces totaling 623 m² (6,703 sq ft). The largest is Georgetown (A,B,C) at 16.2 x 7 m (53 x 23 ft) with a 4 m (13 ft) ceiling. The tallest ceiling on the property is 4 m (13 ft).

Open Georgetown (A,B,C) in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Georgetown (A,B,C)16.2 x 753 x 23113 m² / 1,221 sq ft4 m / 13 ftPublished dimensions
Georgetown C13.4 x 744 x 2394 m² / 1,010 sq ft4 m / 13 ftPublished dimensions
Restaurant - Lunch9.6 x 9.631 x 3192 m² / 992 sq ft3.1 m / 10 ftPublished dimensions
Georgetown Prefunction8.6 x 8.628 x 2874 m² / 797 sq ft3.1 m / 10 ftPublished dimensions
Meeting Room Prefunction Space23.8 x 378 x 1071 m² / 769 sq ft4 m / 13 ftPublished dimensions
Lounge - Reception7.5 x 7.525 x 2556 m² / 606 sq ft3.1 m / 10 ftPublished dimensions
Cleveland Park7.6 x 6.725 x 2251 m² / 548 sq ft4 m / 13 ftPublished dimensions
Georgetown (A)5.2 x 717 x 2336 m² / 392 sq ft4 m / 13 ftPublished dimensions
Georgetown B4.9 x 716 x 2334 m² / 369 sq ft4 m / 13 ftPublished dimensions

What fits in Georgetown (A,B,C)

With a 4 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 25 tiles wide by 4 high (100 tiles, 12.5 x 2 m, 5000 x 800 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 780 kg and draws up to 16 kW (77 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 65 theater, 26 banquet, or 18 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm21 x 6 = 12612.6 x 2 m16128 x 2592567 kg / 1,250 lb11.1 kW, 54 A @ 208 V
Absen PL2.5 Plus V22.5 mm25 x 4 = 10012.5 x 2 m5000 x 800780 kg / 1,720 lb16 kW, 77 A @ 208 V
Absen PL3.9 Plus V23.9 mm25 x 4 = 10012.5 x 2 m3200 x 512780 kg / 1,720 lb14 kW, 67 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 3 of the 9 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Georgetown (A,B,C) is a long room (2.3:1), so put the wall on the short end and expect the back row to be 16.2 m out; a 2.5 mm pitch holds up at that distance.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Washington · All venues