Horizon
AVVenues
Home / Venues / Warrington / Work Space Hub

Work Space Hub

Published dimensionsWarrington

Work Space Hub in Warrington lists 7 event spaces totaling 233 m² (2,503 sq ft). The largest is The Pendle Room at 13.1 x 6.3 m (43 x 21 ft) with a 3.5 m (11 ft) ceiling. The tallest ceiling on the property is 3.5 m (11 ft).

Open The Pendle Room in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
The Pendle Room13.1 x 6.343 x 2183 m² / 888 sq ft3.5 m / 11 ftPublished dimensions
The Boardroom7.2 x 6.324 x 2145 m² / 489 sq ft3.5 m / 11 ftPublished dimensions
The Brook Room8.6 x 4.628 x 1540 m² / 426 sq ft2.4 m / 8 ftPublished dimensions
The Ashton Room5.6 x 4.618 x 1526 m² / 278 sq ft2.4 m / 8 ftPublished dimensions
The Newton Room5.8 x 3.419 x 1120 m² / 212 sq ft2.4 m / 8 ftPublished dimensions
The Willow Room3.3 x 311 x 1010 m² / 107 sq ft2.4 m / 8 ftPublished dimensions
The Zen Room3.3 x 2.911 x 1010 m² / 103 sq ft2.4 m / 8 ftPublished dimensions

What fits in The Pendle Room

With a 3.5 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 20 tiles wide by 3 high (60 tiles, 10 x 1.5 m, 4000 x 600 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 468 kg and draws up to 9.6 kW (46 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 0 theater, 0 banquet, or 0 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm17 x 5 = 8510.2 x 1.7 m13056 x 2160383 kg / 843 lb7.5 kW, 36 A @ 208 V
Absen PL2.5 Plus V22.5 mm20 x 3 = 6010 x 1.5 m4000 x 600468 kg / 1,032 lb9.6 kW, 46 A @ 208 V
Absen PL3.9 Plus V23.9 mm20 x 3 = 6010 x 1.5 m2560 x 384468 kg / 1,032 lb8.4 kW, 40 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Warrington · All venues

Menu
Sign InStart Free Trial