Horizon
AVVenues

Ballroom D at Greater Tacoma Convention Center

Published dimensions

Ballroom D is 26.8 x 15.8 m (88 x 52 ft), 423 m² (4,557 sq ft), with a 7.2 m (24 ft) ceiling.

Open in 3D previz

Plan view

26.8 m / 88 ft15.8 m / 52 ft grid 5 m

LED wall that fits

Under a 7.2 m ceiling with 1.5 m trim and 0.3 m clearance you get 10 rows of 500 mm tile flown. Along the 26.8 m wall a Absen PL2.5 Plus V2 wall runs 42 x 10 (8400 x 2000 px, 3,276 kg, 67.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm35 x 16 = 56021 x 5.4 m26880 x 69122,520 kg / 5,556 lb49.6 kW, 238 A @ 208 V
Absen PL2.5 Plus V22.5 mm42 x 10 = 42021 x 5 m8400 x 20003,276 kg / 7,222 lb67.2 kW, 323 A @ 208 V
Absen PL3.9 Plus V23.9 mm42 x 10 = 42021 x 5 m5376 x 12803,276 kg / 7,222 lb58.8 kW, 283 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Ballroom D holds about 754 theater seats, 308 banquet seats at rounds of 10, or 212 classroom seats. Back row in theater is roughly 19.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Greater Tacoma Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Greater Tacoma Convention Center · Venues in Tacoma

Menu
Sign InStart Free Trial