Centre 200
Centre 200 in Sydney lists 7 event spaces totaling 3,180 m² (34,225 sq ft). The largest is Main Arena at 61 x 25.9 m (200 x 85 ft) with a 12.2 m (40 ft) ceiling. The tallest ceiling on the property is 12.2 m (40 ft).
Open Main Arena in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Main Arena | 61 x 25.9 | 200 x 85 | 1,580 m² / 17,006 sq ft | 12.2 m / 40 ft | Published dimensions | ||
| Buchanan Hall | 17.4 x 35.4 | 57 x 116 | 616 m² / 6,631 sq ft | 5.8 m / 19 ft | Published dimensions | ||
| John Jr. Hanna Concourse | 45.7 x 8.8 | 150 x 29 | 402 m² / 4,329 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| MacDonald Room | 36.6 x 9.1 | 120 x 30 | 333 m² / 3,585 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Room A | 9.1 x 9.1 | 30 x 30 | 83 m² / 891 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Room B | 9.1 x 9.1 | 30 x 30 | 83 m² / 891 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Room C | 9.1 x 9.1 | 30 x 30 | 83 m² / 891 sq ft | 3.7 m / 12 ft | Published dimensions |
What fits in Main Arena
With a 12.2 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 97 tiles wide by 20 high (1940 tiles, 48.5 x 10 m, 19400 x 4000 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 15,132 kg and draws up to 310.4 kW (1492 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 3,324 theater, 1,359 banquet, or 934 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 81 x 30 = 2430 | 48.6 x 10.1 m | 62208 x 12960 | 10,935 kg / 24,107 lb | 215 kW, 1034 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 97 x 20 = 1940 | 48.5 x 10 m | 19400 x 4000 | 15,132 kg / 33,360 lb | 310.4 kW, 1492 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 97 x 20 = 1940 | 48.5 x 10 m | 12416 x 2560 | 15,132 kg / 33,360 lb | 271.6 kW, 1306 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout. Main Arena is a long room (2.4:1), so put the wall on the short end and expect the back row to be 61 m out; a 2.5 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.