Sheffield United Conference & Events
Sheffield United Conference & Events in Sheffield lists 8 event spaces totaling 1,651 m² (17,771 sq ft). The largest is Platinum Suite at 31 x 15.5 m (102 x 51 ft) with a 2.7 m (9 ft) ceiling. The tallest ceiling on the property is 2.7 m (9 ft).
Open Platinum Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Platinum Suite | 31 x 15.5 | 102 x 51 | 481 m² / 5,172 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| The Tony Currie Suite | 10 x 30 | 33 x 98 | 300 m² / 3,229 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| The 1889 Suite | 7.3 x 36 | 24 x 118 | 263 m² / 2,829 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| The International Suite | 24.2 x 10.5 | 79 x 34 | 254 m² / 2,735 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Legends of the Lane | 18.5 x 12 | 61 x 39 | 222 m² / 2,390 sq ft | 2.5 m / 8 ft | Published dimensions | ||
| The 125 Room | 8.5 x 7 | 28 x 23 | 60 m² / 640 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| The Boardroom | 7.9 x 5.8 | 26 x 19 | 46 m² / 493 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| The Executive Boxes (29 in total) | 7.5 x 3.5 | 25 x 11 | 26 m² / 283 sq ft | 2.5 m / 8 ft | Published dimensions |
What fits in Platinum Suite
With a 2.7 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 49 tiles wide by 1 high (49 tiles, 24.5 x 0.5 m, 9800 x 200 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 382 kg and draws up to 7.8 kW (38 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 881 theater, 360 banquet, or 247 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 41 x 2 = 82 | 24.6 x 0.7 m | 31488 x 864 | 369 kg / 813 lb | 7.3 kW, 35 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 49 x 1 = 49 | 24.5 x 0.5 m | 9800 x 200 | 382 kg / 843 lb | 7.8 kW, 38 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 49 x 1 = 49 | 24.5 x 0.5 m | 6272 x 128 | 382 kg / 843 lb | 6.9 kW, 33 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 8 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.