Horizon
AVVenues

Summit - Flex at Seattle Convention Center

Published dimensions

Summit - Flex is 96 x 96 m (315 x 315 ft), 9,216 m² (99,200 sq ft), with a 3.1 m (10 ft) ceiling.

Open in 3D previz

Plan view

96 m / 315 ft96 m / 315 ft grid 10 m

Shape approximate: the venue publishes area only, so this room is drawn as a square of equal area.

LED wall that fits

Under a 3.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 96 m wall a Absen PL2.5 Plus V2 wall runs 153 x 2 (30600 x 400 px, 2,387 kg, 49 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm128 x 3 = 38476.8 x 1 m98304 x 12961,728 kg / 3,810 lb34 kW, 163 A @ 208 V
Absen PL2.5 Plus V22.5 mm153 x 2 = 30676.5 x 1 m30600 x 4002,387 kg / 5,262 lb49 kW, 235 A @ 208 V
Absen PL3.9 Plus V23.9 mm153 x 2 = 30676.5 x 1 m19584 x 2562,387 kg / 5,262 lb42.8 kW, 206 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Summit - Flex holds about 20,293 theater seats, 8,301 banquet seats at rounds of 10, or 5,707 classroom seats. Back row in theater is roughly 89 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Seattle Convention Center

Published dimensions (source), fetched 2026-09-04. All rooms at Seattle Convention Center · Venues in Seattle

Menu
Sign InStart Free Trial