Horizon
AVVenues
Home / Venues / Richmond / Richmond Raceway Complex

Richmond Raceway Complex

Published dimensionsRichmond

Richmond Raceway Complex in Richmond lists 4 event spaces totaling 3,341 m² (35,963 sq ft). The largest is The Old Dominion Building at 57.8 x 57.8 m (190 x 190 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open The Old Dominion Building in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
The Old Dominion Building57.8 x 57.8190 x 1903,341 m² / 35,960 sq ft3.1 m / 10 ftPublished dimensions
Amphitheatre0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions
The Horticulture Garden0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions
Torque Club0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions

What fits in The Old Dominion Building

With a 3.1 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 92 tiles wide by 2 high (184 tiles, 46 x 1 m, 18400 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,435 kg and draws up to 29.4 kW (142 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 7,237 theater, 2,960 banquet, or 2,035 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm77 x 3 = 23146.2 x 1 m59136 x 12961,040 kg / 2,292 lb20.4 kW, 98 A @ 208 V
Absen PL2.5 Plus V22.5 mm92 x 2 = 18446 x 1 m18400 x 4001,435 kg / 3,164 lb29.4 kW, 142 A @ 208 V
Absen PL3.9 Plus V23.9 mm92 x 2 = 18446 x 1 m11776 x 2561,435 kg / 3,164 lb25.8 kW, 124 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Richmond · All venues

Menu
Sign InStart Free Trial