The Marmara Park Avenue
The Marmara Park Avenue in New York lists 2 event spaces totaling 124 m² (1,336 sq ft). The largest is The Block- The Park & Lexington Meeting Room at 14.8 x 6.7 m (49 x 22 ft) with a 2.4 m (8 ft) ceiling. The tallest ceiling on the property is 2.4 m (8 ft).
Open The Block- The Park & Lexington Meeting Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Block- The Park & Lexington Meeting Room | 14.8 x 6.7 | 49 x 22 | 99 m² / 1,068 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Nook | 5.8 x 4.3 | 19 x 14 | 25 m² / 268 sq ft | 2.4 m / 8 ft | Published dimensions |
What fits in The Block- The Park & Lexington Meeting Room
With a 2.4 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 23 tiles wide by 1 high (23 tiles, 11.5 x 0.5 m, 4600 x 200 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 179 kg and draws up to 3.7 kW (18 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 33 theater, 13 banquet, or 9 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 19 x 1 = 19 | 11.4 x 0.3 m | 14592 x 432 | 86 kg / 188 lb | 1.7 kW, 8 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 23 x 1 = 23 | 11.5 x 0.5 m | 4600 x 200 | 179 kg / 396 lb | 3.7 kW, 18 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 23 x 1 = 23 | 11.5 x 0.5 m | 2944 x 128 | 179 kg / 396 lb | 3.2 kW, 15 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 2 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. The Block- The Park & Lexington Meeting Room is a long room (2.2:1), so put the wall on the short end and expect the back row to be 14.8 m out; a 2.5 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.