Horizon
AVVenues
Home / Venues / New York / The Kimberly Hotel

The Kimberly Hotel

Published dimensionsNew York

The Kimberly Hotel in New York lists 4 event spaces totaling 425 m² (4,569 sq ft). The largest is Rooftop Bar and Lounge /Upsatairs at 16.7 x 16.7 m (55 x 55 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Rooftop Bar and Lounge /Upsatairs in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Rooftop Bar and Lounge /Upsatairs16.7 x 16.755 x 55279 m² / 3,002 sq ft3.1 m / 10 ftPublished dimensions
Upstairs4.4 x 17.414 x 5777 m² / 825 sq ft3.1 m / 10 ftPublished dimensions
Conference Room8.3 x 8.327 x 2769 m² / 742 sq ft2.7 m / 9 ftPublished dimensions
The VIP Room0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions

What fits in Rooftop Bar and Lounge /Upsatairs

With a 3.1 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 26 tiles wide by 2 high (52 tiles, 13 x 1 m, 5200 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 406 kg and draws up to 8.3 kW (40 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 433 theater, 177 banquet, or 121 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm22 x 3 = 6613.2 x 1 m16896 x 1296297 kg / 655 lb5.8 kW, 28 A @ 208 V
Absen PL2.5 Plus V22.5 mm26 x 2 = 5213 x 1 m5200 x 400406 kg / 894 lb8.3 kW, 40 A @ 208 V
Absen PL3.9 Plus V23.9 mm26 x 2 = 5213 x 1 m3328 x 256406 kg / 894 lb7.3 kW, 35 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in New York · All venues

Menu
Sign InStart Free Trial