DoubleTree by Hilton Hotel New York Times Square West
DoubleTree by Hilton Hotel New York Times Square West in New York lists 4 event spaces totaling 213 m² (2,293 sq ft). The largest is Hudson/Lincoln Room at 9.1 x 9.1 m (30 x 30 ft) with a 2.4 m (8 ft) ceiling. The tallest ceiling on the property is 3.4 m (11 ft).
Open Hudson/Lincoln Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hudson/Lincoln Room | 9.1 x 9.1 | 30 x 30 | 83 m² / 891 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Lincoln Room | 4 x 11.6 | 13 x 38 | 46 m² / 499 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Hudson Room | 9.1 x 4.6 | 30 x 15 | 42 m² / 451 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Lincoln | 9.1 x 4.6 | 30 x 15 | 42 m² / 451 sq ft | 2.4 m / 8 ft | Published dimensions |
What fits in Hudson/Lincoln Room
With a 2.4 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 14 tiles wide by 1 high (14 tiles, 7 x 0.5 m, 2800 x 200 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 109 kg and draws up to 2.2 kW (11 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 0 theater, 0 banquet, or 0 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 12 x 1 = 12 | 7.2 x 0.3 m | 9216 x 432 | 54 kg / 119 lb | 1.1 kW, 5 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 14 x 1 = 14 | 7 x 0.5 m | 2800 x 200 | 109 kg / 241 lb | 2.2 kW, 11 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 14 x 1 = 14 | 7 x 0.5 m | 1792 x 128 | 109 kg / 241 lb | 2 kW, 9 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.