National Harbor I at AC Hotel National Harbor Washington, DC Area
National Harbor I is 11.6 x 11.9 m (38 x 39 ft), 138 m² (1,485 sq ft), with a 3.5 m (12 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 11.9 m wall a Absen PL2.5 Plus V2 wall runs 19 x 3 (3800 x 600 px, 445 kg, 9.1 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 15 x 5 = 75 | 9 x 1.7 m | 11520 x 2160 | 338 kg / 744 lb | 6.6 kW, 32 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 19 x 3 = 57 | 9.5 x 1.5 m | 3800 x 600 | 445 kg / 980 lb | 9.1 kW, 44 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 19 x 3 = 57 | 9.5 x 1.5 m | 2432 x 384 | 445 kg / 980 lb | 8 kW, 38 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, National Harbor I holds about 120 theater seats, 49 banquet seats at rounds of 10, or 33 classroom seats. Back row in theater is roughly 4.9 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at AC Hotel National Harbor Washington, DC Area
- Courtyard16.7 x 16.7 m (55 x 55 ft) · 3.1 m ceiling
- National Harbor II9.4 x 14.3 m (31 x 47 ft) · 3.5 m ceiling
- National Harbor III8.2 x 10.1 m (27 x 33 ft) · 3.5 m ceiling
- Media Salon6.1 x 4.3 m (20 x 14 ft) · 3.4 m ceiling
- Meeting Salon6.1 x 4.3 m (20 x 14 ft) · 3.4 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at AC Hotel National Harbor Washington, DC Area · Venues in National Harbor