Brewhouse Inn & Suites
Brewhouse Inn & Suites in Milwaukee lists 6 event spaces totaling 1,309 m² (14,093 sq ft). The largest is Kettle Atrium at 10.7 x 47.5 m (35 x 156 ft) with a 18.3 m (60 ft) ceiling. The tallest ceiling on the property is 18.3 m (60 ft).
Open Kettle Atrium in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Kettle Atrium | 10.7 x 47.5 | 35 x 156 | 508 m² / 5,470 sq ft | 18.3 m / 60 ft | Published dimensions | ||
| On Tap Courtyard | 18.3 x 26.8 | 60 x 88 | 490 m² / 5,279 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| On Tap Private Space | 13.4 x 7.6 | 44 x 25 | 102 m² / 1,096 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| Mezzanine | 7 x 13.7 | 23 x 45 | 96 m² / 1,032 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Lobby | 9.6 x 9.6 | 31 x 31 | 92 m² / 992 sq ft | 3 m / 10 ft | Published dimensions | ||
| Conference Room | 4 x 5.2 | 13 x 17 | 21 m² / 224 sq ft | 3 m / 10 ft | Published dimensions |
What fits in Kettle Atrium
With a 18.3 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 76 tiles wide by 32 high (2432 tiles, 38 x 16 m, 15200 x 6400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 18,970 kg and draws up to 389.1 kW (1871 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 942 theater, 385 banquet, or 265 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 63 x 48 = 3024 | 37.8 x 16.2 m | 48384 x 20736 | 13,608 kg / 30,000 lb | 267.6 kW, 1287 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 76 x 32 = 2432 | 38 x 16 m | 15200 x 6400 | 18,970 kg / 41,820 lb | 389.1 kW, 1871 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 76 x 32 = 2432 | 38 x 16 m | 9728 x 4096 | 18,970 kg / 41,820 lb | 340.5 kW, 1637 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 3 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.