Aloft by Marriott Milwaukee Downtown
Aloft by Marriott Milwaukee Downtown in Milwaukee lists 5 event spaces totaling 409 m² (4,405 sq ft). The largest is Tactic 4 & 5 at 19.5 x 7.3 m (64 x 24 ft) with a 2.4 m (8 ft) ceiling. The tallest ceiling on the property is 3.4 m (11 ft).
Open Tactic 4 & 5 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Tactic 4 & 5 | 19.5 x 7.3 | 64 x 24 | 142 m² / 1,533 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Tactic 2 | 9.1 x 9.1 | 30 x 30 | 83 m² / 891 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Tactic 5 | 10.1 x 7.3 | 33 x 24 | 74 m² / 793 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Tactic 3 | 9.1 x 6.1 | 30 x 20 | 56 m² / 597 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Tactic 4 | 7.4 x 7.4 | 24 x 24 | 55 m² / 590 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Tactic 4 & 5
With a 2.4 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 31 tiles wide by 1 high (31 tiles, 15.5 x 0.5 m, 6200 x 200 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 242 kg and draws up to 5 kW (24 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 129 theater, 53 banquet, or 36 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 26 x 1 = 26 | 15.6 x 0.3 m | 19968 x 432 | 117 kg / 258 lb | 2.3 kW, 11 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 31 x 1 = 31 | 15.5 x 0.5 m | 6200 x 200 | 242 kg / 533 lb | 5 kW, 24 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 31 x 1 = 31 | 15.5 x 0.5 m | 3968 x 128 | 242 kg / 533 lb | 4.3 kW, 21 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 5 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Tactic 4 & 5 is a long room (2.7:1), so put the wall on the short end and expect the back row to be 19.5 m out; a 2.5 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.