Pyramide Mainz
Pyramide Mainz in Mainz lists 3 event spaces totaling 2,548 m² (27,429 sq ft). The largest is CENTER at 38.7 x 38.7 m (127 x 127 ft) with a 8 m (26 ft) ceiling. The tallest ceiling on the property is 18 m (59 ft).
Open CENTER in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| CENTER | 38.7 x 38.7 | 127 x 127 | 1,498 m² / 16,121 sq ft | 8 m / 26 ft | Published dimensions | ||
| PEAK | 28.3 x 28.3 | 93 x 93 | 801 m² / 8,621 sq ft | 18 m / 59 ft | Published dimensions | ||
| PANORAMA | 15.8 x 15.8 | 52 x 52 | 250 m² / 2,687 sq ft | 6 m / 20 ft | Published dimensions |
What fits in CENTER
With a 8 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 61 tiles wide by 12 high (732 tiles, 30.5 x 6 m, 12200 x 2400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 5,710 kg and draws up to 117.1 kW (563 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 3,141 theater, 1,285 banquet, or 883 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 51 x 18 = 918 | 30.6 x 6.1 m | 39168 x 7776 | 4,131 kg / 9,107 lb | 81.2 kW, 391 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 61 x 12 = 732 | 30.5 x 6 m | 12200 x 2400 | 5,710 kg / 12,587 lb | 117.1 kW, 563 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 61 x 12 = 732 | 30.5 x 6 m | 7808 x 1536 | 5,710 kg / 12,587 lb | 102.5 kW, 493 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.