UBI Conference Hall - Business
UBI Conference Hall - Business in Kiev lists 3 event spaces totaling 796 m² (8,566 sq ft). The largest is Gallary and Exhibition Area at 22.4 x 22.4 m (73 x 73 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Gallary and Exhibition Area in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Gallary and Exhibition Area | 22.4 x 22.4 | 73 x 73 | 502 m² / 5,401 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Conference Hall | 16.4 x 16.4 | 54 x 54 | 269 m² / 2,895 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Mini Conference Hall | 5 x 5 | 16 x 16 | 25 m² / 269 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Gallary and Exhibition Area
With a 3.1 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 35 tiles wide by 2 high (70 tiles, 17.5 x 1 m, 7000 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 546 kg and draws up to 11.2 kW (54 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 928 theater, 379 banquet, or 261 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 29 x 3 = 87 | 17.4 x 1 m | 22272 x 1296 | 392 kg / 863 lb | 7.7 kW, 37 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 35 x 2 = 70 | 17.5 x 1 m | 7000 x 400 | 546 kg / 1,204 lb | 11.2 kW, 54 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 35 x 2 = 70 | 17.5 x 1 m | 4480 x 256 | 546 kg / 1,204 lb | 9.8 kW, 47 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 3 of the 3 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.