Horizon
AVVenues

Room 3 at CCD Convention Center Düsseldorf

Published dimensions

Room 3 is 21.7 x 21.7 m (71 x 71 ft), 471 m² (5,069 sq ft), with a 4.5 m (15 ft) ceiling.

Open in 3D previz

Plan view

21.7 m / 71 ft21.7 m / 71 ft grid 1 m

Shape approximate: the venue publishes area only, so this room is drawn as a square of equal area.

LED wall that fits

Under a 4.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 5 rows of 500 mm tile flown. Along the 21.7 m wall a Absen PL2.5 Plus V2 wall runs 34 x 5 (6800 x 1000 px, 1,326 kg, 27.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm28 x 7 = 19616.8 x 2.4 m21504 x 3024882 kg / 1,944 lb17.3 kW, 83 A @ 208 V
Absen PL2.5 Plus V22.5 mm34 x 5 = 17017 x 2.5 m6800 x 10001,326 kg / 2,923 lb27.2 kW, 131 A @ 208 V
Absen PL3.9 Plus V23.9 mm34 x 5 = 17017 x 2.5 m4352 x 6401,326 kg / 2,923 lb23.8 kW, 114 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Room 3 holds about 859 theater seats, 351 banquet seats at rounds of 10, or 241 classroom seats. Back row in theater is roughly 14.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at CCD Convention Center Düsseldorf

Published dimensions (source), fetched 2026-09-05. All rooms at CCD Convention Center Düsseldorf · Venues in Dusseldorf