Meeting Place at Hyatt Place DFW
Meeting Place is 19.5 x 9.4 m (64 x 31 ft), 183 m² (1,973 sq ft), with a 3 m (10 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 19.5 m wall a Absen PL2.5 Plus V2 wall runs 31 x 2 (6200 x 400 px, 484 kg, 9.9 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 26 x 3 = 78 | 15.6 x 1 m | 19968 x 1296 | 351 kg / 774 lb | 6.9 kW, 33 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 31 x 2 = 62 | 15.5 x 1 m | 6200 x 400 | 484 kg / 1,066 lb | 9.9 kW, 48 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 31 x 2 = 62 | 15.5 x 1 m | 3968 x 256 | 484 kg / 1,066 lb | 8.7 kW, 42 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Place holds about 220 theater seats, 90 banquet seats at rounds of 10, or 62 classroom seats. Back row in theater is roughly 12.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Hyatt Place DFW
- Meeting Place 312.2 x 9.1 m (40 x 30 ft) · 3 m ceiling
- Meeting Place 14 x 9.1 m (13 x 30 ft) · 3 m ceiling
- Meeting Place 24 x 9.1 m (13 x 30 ft) · 3 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Hyatt Place DFW · Venues in Dallas