Horizon
AVVenues
Home / Venues / Grand Hyatt DFW / Gateway I & II or III & IV

Gateway I & II or III & IV at Grand Hyatt DFW

Published dimensions

Gateway I & II or III & IV is 13.4 x 10.4 m (44 x 34 ft), 139 m² (1,500 sq ft), with a 4.9 m (16 ft) ceiling.

Open in 3D previz

Plan view

13.4 m / 44 ft10.4 m / 34 ft grid 1 m

LED wall that fits

Under a 4.9 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 13.4 m wall a Absen PL2.5 Plus V2 wall runs 21 x 6 (4200 x 1200 px, 983 kg, 20.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm17 x 9 = 15310.2 x 3 m13056 x 3888689 kg / 1,518 lb13.5 kW, 65 A @ 208 V
Absen PL2.5 Plus V22.5 mm21 x 6 = 12610.5 x 3 m4200 x 1200983 kg / 2,167 lb20.2 kW, 97 A @ 208 V
Absen PL3.9 Plus V23.9 mm21 x 6 = 12610.5 x 3 m2688 x 768983 kg / 2,167 lb17.6 kW, 85 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Gateway I & II or III & IV holds about 123 theater seats, 50 banquet seats at rounds of 10, or 34 classroom seats. Back row in theater is roughly 6.4 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Grand Hyatt DFW

Published dimensions (source), fetched 2026-09-05. All rooms at Grand Hyatt DFW · Venues in Dallas