Bolton Arena
Bolton Arena in Bolton lists 7 event spaces totaling 437 m² (4,706 sq ft). The largest is Boardroom Suite at 23.7 x 5.5 m (78 x 18 ft) with a 2.7 m (9 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Boardroom Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Boardroom Suite | 23.7 x 5.5 | 78 x 18 | 130 m² / 1,404 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| East Lecture Room | 10.1 x 8.7 | 33 x 29 | 88 m² / 946 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| West Lecture Room | 10.1 x 8.7 | 33 x 29 | 88 m² / 946 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Conference Room 1 | 9 x 5.5 | 30 x 18 | 50 m² / 533 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Conference Room 2 | 9 x 5.5 | 30 x 18 | 50 m² / 533 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Boardroom | 5.8 x 5.5 | 19 x 18 | 32 m² / 343 sq ft | 2.7 m / 9 ft | Published dimensions | ||
| Theatre | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Boardroom Suite
With a 2.7 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 37 tiles wide by 1 high (37 tiles, 18.5 x 0.5 m, 7400 x 200 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 289 kg and draws up to 5.9 kW (28 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 103 theater, 42 banquet, or 29 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 31 x 2 = 62 | 18.6 x 0.7 m | 23808 x 864 | 279 kg / 615 lb | 5.5 kW, 26 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 37 x 1 = 37 | 18.5 x 0.5 m | 7400 x 200 | 289 kg / 636 lb | 5.9 kW, 28 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 37 x 1 = 37 | 18.5 x 0.5 m | 4736 x 128 | 289 kg / 636 lb | 5.2 kW, 25 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Boardroom Suite is a long room (4.3:1), so put the wall on the short end and expect the back row to be 23.7 m out; a 2.5 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.