Horizon
AVVenues
Home / Venues / Berlin / Messe Berlin

Messe Berlin

Published dimensionsBerlin

Messe Berlin in Berlin lists 4 event spaces totaling 12,367 m² (133,121 sq ft). The largest is Hall 9 a to c at 87.6 x 87.6 m (287 x 287 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Hall 9 a to c in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Hall 9 a to c87.6 x 87.6287 x 2877,674 m² / 82,600 sq ft3.1 m / 10 ftPublished dimensions
Hall 1956.4 x 56.4185 x 1853,181 m² / 34,240 sq ft3.1 m / 10 ftPublished dimensions
Hall 7.3 Berlin27.5 x 27.590 x 90756 m² / 8,141 sq ft3.1 m / 10 ftPublished dimensions
Hall 7.3 Europa27.5 x 27.590 x 90756 m² / 8,141 sq ft3.1 m / 10 ftPublished dimensions

What fits in Hall 9 a to c

With a 3.1 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 140 tiles wide by 2 high (280 tiles, 70 x 1 m, 28000 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,184 kg and draws up to 44.8 kW (215 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 16,866 theater, 6,899 banquet, or 4,743 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
Absen KLCOB 0.780.78 mm116 x 3 = 34869.6 x 1 m89088 x 12961,566 kg / 3,452 lb30.8 kW, 148 A @ 208 V
Absen PL2.5 Plus V22.5 mm140 x 2 = 28070 x 1 m28000 x 4002,184 kg / 4,815 lb44.8 kW, 215 A @ 208 V
Absen PL3.9 Plus V23.9 mm140 x 2 = 28070 x 1 m17920 x 2562,184 kg / 4,815 lb39.2 kW, 188 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.