Aotea Centre
Aotea Centre in Auckland lists 9 event spaces totaling 4,628 m² (49,817 sq ft). The largest is Air New Zeland Foyer at 33.2 x 33.2 m (109 x 109 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Air New Zeland Foyer in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Air New Zeland Foyer | 33.2 x 33.2 | 109 x 109 | 1,102 m² / 11,864 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Lower NZI | 30.1 x 30.1 | 99 x 99 | 906 m² / 9,752 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| BNZ Foyer | 28.3 x 28.3 | 93 x 93 | 801 m² / 8,621 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Owens Foyer | 28.3 x 28.3 | 93 x 93 | 801 m² / 8,621 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Upper NZI | 22.8 x 22.8 | 75 x 75 | 520 m² / 5,595 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Limelight | 17.8 x 17.8 | 58 x 58 | 317 m² / 3,410 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Goodman Fielder Room | 13.4 x 13.4 | 44 x 44 | 180 m² / 1,933 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| ASB Theatre | 1 x 1 | 3 x 3 | 1 m² / 11 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Herald Theatre | 1 x 1 | 3 x 3 | 1 m² / 11 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Air New Zeland Foyer
With a 3.1 m ceiling, a flown wall of Absen PL2.5 Plus V2 (2.5 mm) runs 53 tiles wide by 2 high (106 tiles, 26.5 x 1 m, 10600 x 400 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 827 kg and draws up to 17 kW (82 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,262 theater, 925 banquet, or 636 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 44 x 3 = 132 | 26.4 x 1 m | 33792 x 1296 | 594 kg / 1,310 lb | 11.7 kW, 56 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 53 x 2 = 106 | 26.5 x 1 m | 10600 x 400 | 827 kg / 1,823 lb | 17 kW, 82 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 53 x 2 = 106 | 26.5 x 1 m | 6784 x 256 | 827 kg / 1,823 lb | 14.8 kW, 71 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 9 of the 9 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.