Meeting Room 2 at Hampton Inn & Suites Atlanta Buckhead Place
Meeting Room 2 is 9.8 x 6.1 m (32 x 20 ft), 60 m² (644 sq ft), with a 4 m (13 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 4 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 9.8 m wall a Absen PL2.5 Plus V2 wall runs 15 x 4 (3000 x 800 px, 468 kg, 9.6 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| Absen KLCOB 0.78 | 0.78 mm | 13 x 6 = 78 | 7.8 x 2 m | 9984 x 2592 | 351 kg / 774 lb | 6.9 kW, 33 A @ 208 V |
| Absen PL2.5 Plus V2 | 2.5 mm | 15 x 4 = 60 | 7.5 x 2 m | 3000 x 800 | 468 kg / 1,032 lb | 9.6 kW, 46 A @ 208 V |
| Absen PL3.9 Plus V2 | 3.9 mm | 15 x 4 = 60 | 7.5 x 2 m | 1920 x 512 | 468 kg / 1,032 lb | 8.4 kW, 40 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Meeting Room 2 holds about 0 theater seats, 0 banquet seats at rounds of 10, or 0 classroom seats. Back row in theater is roughly 2.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Hampton Inn & Suites Atlanta Buckhead Place
- Ballroom9.8 x 18.6 m (32 x 61 ft) · 4 m ceiling
- Holmes Ballroom19.2 x 9.4 m (63 x 31 ft) · 4 m ceiling
- Holmes Room 16.4 x 9.4 m (21 x 31 ft) · 4 m ceiling
- Holmes Room 26.4 x 9.4 m (21 x 31 ft) · 4 m ceiling
- Holmes Room 36.4 x 9.4 m (21 x 31 ft) · 4 m ceiling
- Meeting Room 39.4 x 6.4 m (31 x 21 ft) · 4 m ceiling
- Meeting Room 19.8 x 6.1 m (32 x 20 ft) · 4 m ceiling